(1). Climate type: 25 / 85 / 21
(2) Capacitance tolerance: ±5%, ±10%
(3) Testing voltage: 
 (a)       Between leading-out: 1.75UR, 10S no breakdown
 (b)       Between leading-out end and shell: 2,200V AC, 10S no breakdown
(4) Insulation resistance: 
 (a)       Between leading-out ends: ≥3,000MΩ
 (b)       Between leading-out end and shell: ≥1,000MΩ
(5) Tangent of loss angle: tgδ≤0.002 (50Hz)
          